Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Article in English, Portuguese | LILACS | ID: biblio-1442131

ABSTRACT

ABSTRACT OBJECTIVE To estimate the prevalence of unplanned pregnancy in eight public university hospitals, distributed in the five regions that make up Brazil. METHODS A secondary analysis of a national multicenter cross-sectional study, carried out in eight public university hospitals between June 1 and August 31, 2020, in Brazil. Convenience sample including women who gave birth within sixty consecutive days and met the following criteria: over 18 years old; gestational age over 36 weeks at delivery; with a single and live newborn, without malformations. RESULTS Sample composed of 1,120 postpartum women, of whom 756 (67.5%) declared that the pregnancy had not been planned. The median prevalence of unplanned pregnancy was 59.7%. The prevalence of unplanned pregnancy across hospitals differed significantly: Campinas (54.8%), Porto Alegre (58.2%), Florianópolis (59%), Teresina (61.2%), Brasília (64.3%), São Paulo (64.6%), Campo Grande (73.9%) and Manaus (95.3%) (p < 0.001). Factors significantly associated with unplanned pregnancy were maternal age, black color, lower family income, greater number of children, greater number of people living in household, and not having a partner. CONCLUSION In the studied sample, about two thirds of the pregnancies were declared as unplanned. The prevalence of unplanned pregnancies was related to social and demographic factors and varied significantly across the university hospitals evaluated.


RESUMO OBJETIVO Estimar a prevalência de gestação não planejada (GNP) em oito hospitais públicos universitários, distribuídos nas cinco regiões que compõem o Brasil. MÉTODOS Análise secundária de um estudo transversal multicêntrico nacional, realizado em oito hospitais universitários públicos, entre 1º de junho e 31 de agosto de 2020, no Brasil. Amostra por conveniência incluindo mulheres que deram à luz em período de sessenta dias consecutivos e atenderam aos seguintes critérios: maiores de 18 anos; idade gestacional acima de 36 semanas no parto; com recém-nascido único e vivo, sem malformações. RESULTADOS Amostra composta por 1.120 puérperas, das quais 756 (67,5%) declararam que a gravidez não tinha sido programada. A mediana da prevalência de GNP foi de 59,7%. Observou-se diferença significativa na prevalência de GNP entre os hospitais: Campinas (54,8%), Porto Alegre (58,2%), Florianópolis (59%), Teresina (61,2%), Brasília (64,3%), São Paulo (64,6%), Campo Grande (73,9%) e Manaus (95,3%) (p < 0,001). Foram fatores significativamente associados a GNP a idade materna, cor negra, menor renda familiar, maior número de filhos, maior número de pessoas convivendo em casa e não ter parceiro. CONCLUSÃO Na amostra estudada, cerca de dois terços das gestações foram declaradas como não programadas. A prevalência de gestação não planejada teve relação com fatores sociais e demográficos e variou significativamente entre os hospitais universitários avaliados.


Subject(s)
Humans , Female , Pregnancy , Contraception , Pregnancy, Unplanned , Reproductive Rights , Family Development Planning
2.
Clinics ; 78: 100311, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1528420

ABSTRACT

Abstract Objective Gastroschisis (GS) is a congenital anomaly in the abdominal wall with the intestinal loops exiting laterally to the umbilicus. The contact of the loops with Amniotic Fluid (AF) causes an inflammatory process in the exposed part, leading to an extended hospital stay and an increased risk of morbidity due to alterations related to intestinal motility. The authors aimed to evaluate the time of exposure to the AF in the experimental GS and to search for potential biomarkers of intestinal inflammation by measuring microRNAs. Methods Rat fetuses were divided into three groups: a) CONTROL, b) GS reared on day 18 (GS = 18), and c) GS reared on day 19.5 (GS = 19) (term = 22 days). On day 21.5, the fetuses were removed for biometric parameters and biochemical analyses: 1) Biometrics: Body and Intestinal Weight (BW, IW), and intestinal-body weight ratio (IW/BW); 2) Descriptive histopathology and 3) miR-143 quantification by real-time Polymerase Chain Reaction (PCR). Results BW was higher in CONTROL than GS 18 and G19 (p < 0.05). IW, IW/BW, intestinal water, and mRNA-143 were higher in GS 18 and GS 19 than in CONTROL, and GS 18 was higher than GS 19 (p < 0.05). The average of the inflammation score from the intestinal wall with mucosal inflammation and intra-epithelial lymphocytes shows worst in GS 18 and GS 19 vs. CONTROL (p < 0.05). Conclusions The tissue expression of mRNA-143 and the morphological changes in the intestine of GS worsened according to the time of exposure to AF, which could be a possible marker of fetal intestinal damage.

3.
Rev. bras. ginecol. obstet ; 43(12): 932-939, Dec. 2021. tab
Article in English | LILACS | ID: biblio-1357094

ABSTRACT

Abstract Objective To study maternal anxiety in pregnant women without comorbidities in the context of the COVID-19 outbreak in Brazil and to study maternal knowledge and concerns about the pandemic. Methods This is a secondary analysis from a national multicenter cross-sectional study performed in 10 cities, from June to August, 2020, in Brazil. Interviewed postpartum women, without medical or obstetrical comorbidities, were included in the present subanalysis. A structured questionnaire and the Beck Anxiety Inventory (BAI) were applied. Results Out of the 1,662 women, 763 (45.9%) met the criteria for the current analysis and 16.1% presented with moderate and 11.5% with severe maternal anxiety. Moderate or severe maternal anxiety was associated with high school education (odds ratio [OR]:1.58; 95% confidence interval [CI]:1.04-2.40). The protective factor was cohabiting with a partner (OR: 0.46; 95%CI: 0.29-0.73). There was a positive correlation between the total BAI score and receiving information about care in the pandemic (rpartial 0.15; p < 0.001); concern about vertical transmission of COVID-19 (rpartial 0.10; p = 0.01); receiving information about breastfeeding (rpartial 0.08; p = 0.03); concerns about prenatal care (rpartial 0.10; p = 0.01), and concerns about the baby contracting COVID-19 (rpartial 0.11; p = 0.004). The correlation was negative in the following aspects: self-confidence in protecting from COVID-19 (rpartial 0.08; p = 0.04), having learned (rpartial 0.09; p = 0.01) and self-confidence in breastfeeding (rpartial 0.22; p < 0.001) in the context of the pandemic. Conclusion The anxiety of pregnant women without medical or obstetrical comorbidities was associated to high school educational level and not living with a partner during the COVID-19 pandemic. Self-confidence in protecting against COVID-19 and knowledge about breastfeeding care during the pandemic reduced maternal anxiety.


Resumo Objetivo Estudar a ansiedade materna em gestantes sem comorbidades no contexto do surto de COVID-19 no Brasil e estudar o conhecimento e as preocupações maternas sobre a pandemia. Métodos Trata-se de análise secundária de um estudo transversal multicêntrico nacional realizado em 10 cidades, de junho a agosto de 2020, no Brasil. Mulheres no pós-parto entrevistadas, sem comorbidades médicas ou obstétricas, foram incluídas nesta subanálise. Foram aplicados um questionário estruturado e o Inventário de Ansiedade de Beck (BAI, na sigla em inglês). Resultados Das 1.662 mulheres, 763 (45,9%) atenderam aos critérios da análise atual e 16,1% apresentaram ansiedade materna moderada e 11,5% ansiedade materna grave. A ansiedade materna moderada ou grave foi associada à escolaridade no ensino médio (odds ratio [OR]: 1,58; intervalo de confiança [IC] 95%: 1,04-2,40). O fator protetor foi coabitar com companheiro (OR: 0,46; IC95%: 0,29-0,73). Houve correlação positiva entre a pontuação total do BAI e o recebimento de informações sobre cuidados na pandemia (rparcial 0,15; p < 0,001); preocupação com a transmissão vertical de COVID-19 (rparcial 0,10; p = 0,01); receber informações sobre amamentação (rparcial 0,08; p = 0,03); preocupações sobre cuidados pré-natais (rparcial 0,10; p = 0,01) e preocupações sobre o bebê contrair COVID-19 (rparcial 0,11; p = 0,004). A correlação foi negativa com os seguintes aspectos: ter autoconfiança para se proteger (rparcial 0,08; p = 0,04), aprender (rparcial 0,09; p = 0,01) e ter autoconfiança para amamentar (rparcial 0,22; p < 0,001) no contexto da pandemia. Conclusão A ansiedade de gestantes sem comorbidades médicas ou obstétricas esteve associada à escolaridade no ensino médio e não morar com companheiro durante a pandemia de COVID-19. A autoconfiança na proteção contra COVID-19 e o conhecimento sobre os cuidados com a amamentação durante a pandemia reduziram a ansiedade materna.


Subject(s)
Humans , Female , Pregnancy , Pregnant Women , COVID-19 , Anxiety/epidemiology , Brazil/epidemiology , Cross-Sectional Studies , Depression , Pandemics , SARS-CoV-2
4.
Rev. bras. ginecol. obstet ; 38(3): 120-126, Mar. 2016. tab, graf
Article in English | LILACS | ID: lil-781453

ABSTRACT

Purpose To evaluate the precision of both two- and three-dimensional ultrasonography in determining vertebral lesion level (the first open vertebra) in patients with spina bifida. Methods This was a prospective longitudinal study comprising of fetuses with open spina bifida who were treated in the fetal medicine division of the department of obstetrics of Hospital das Clínicas of the Universidade de São Paulo between 2004 and 2013. Vertebral lesion level was established by using both two- and three-dimensional ultrasonography in 50 fetuses (two examiners in each method). The lesion level in the neonatal period was established by radiological assessment of the spine. All pregnancies were followed in our hospital prenatally, and delivery was scheduled to allow immediate postnatal surgical correction. Results Two-dimensional sonography precisely estimated the spina bifida level in 53% of the cases. The estimate error was within one vertebra in 80% of the cases, in up to two vertebrae in 89%, and in up to three vertebrae in 100%, showing a good interobserver agreement. Three-dimensional ultrasonography precisely estimated the lesion level in 50% of the cases. The estimate error was within one vertebra in 82% of the cases, in up to two vertebrae in 90%, and in up to three vertebrae in 100%, also showing good interobserver agreement. Whenever an estimate error was observed, both two- and three-dimensional ultrasonography scans tended to underestimate the true lesion level (55.3% and 62% of the cases, respectively). Conclusions No relevant difference in diagnostic performance was observed between the two- and three-dimensional ultrasonography. The use of three-dimensional ultrasonography showed no additional benefit in diagnosing the lesion level in the fetuses with spina bifida. Errors in both methods showed a tendency to underestimate lesion level.


Objetivo Avaliar a precisão da ultrassonografia bidimensional e tridimensional para a determinação do nível da lesão vertebral em casos de fetos portadores de espinha bífida. Métodos Estudo prospectivo longitudinal, compreendendo fetos portadores de espinha bífida assistidos no setor de medicina fetal de hospital de ensino do Sudeste do Brasil, entre os anos de 2004 e 2013. Foram incluídos 50 fetos portadores de espinha bífida pela ultrassonografia bidimensional e tridimensional (dois examinadores em cadamétodo) comrelação ao nível da lesão. O nível exato da lesão foi verificado usando radiografia após o nascimento. Resultados A ultrassonografia bidimensional estimou corretamente o nível de espinha bífida em 53,0% dos casos. Em 80,0% dos casos a estimativa ocorreu com erro de uma vértebra; 89,0% em até duas vértebras e de 100,0% em até três vértebras. A ultrassonografia tridimensional estimou corretamente o nível de espinha bífida em 50,0% dos casos. Em 82,0% dos casos, a estimativa ocorreu com erro de uma vértebra; 90,0% em até duas vértebras e de 100,0% em até três vértebras. Nos casos em que houve erro na estimativa do nível da lesão, tanto na avaliação bidimensional quanto na tridimensional, observou-se tendência a subestimar o nível da lesão vertebral (55,3% na avaliação bidimensional e 62,0% na tridimensional), ou seja, colocando o nível ultrassonográfico mais baixo que o observado no pós-natal. Conclusões Não houve diferenças relevantes entre o desempenho diagnóstico da ultrassonografia bidimensional e tridimensional para determinação do nível da lesão vertebral nos casos de fetos portadores de espinha bífida. Tendência a subestimação do nível de lesão nos casos em que houve erro tanto na ultrassonografia bidimensional quanto na tridimensional.


Subject(s)
Humans , Female , Pregnancy , Imaging, Three-Dimensional , Spinal Dysraphism/diagnostic imaging , Ultrasonography, Prenatal/methods , Fetus , Longitudinal Studies , Prospective Studies
5.
Rev. Assoc. Med. Bras. (1992) ; 58(5): 587-593, set.-out. 2012. tab
Article in English | LILACS | ID: lil-653772

ABSTRACT

OBJECTIVE: To evaluate the association between Apgar scores of less than seven at five minutes (AS5min < 7) and antenatal factors and postnatal outcomes. METHODS: A retrospective cohort and case-control study of 27,252 consecutive term newborns in a low risk obstetrical population between January 2003 and December 2010. Maternal and infant databases were reviewed from all cases with AS5min < 7 (n = 121; 0.4%) and 363 cases with AS5min > 7 at 5 minutes who were randomly selected by a computer program. The main outcomes were neonatal death, newborn respiratory distress, need for orotracheal intubation and neonatal intensive care unit (NICU), and hypoxic-ischemic-encephalopathy. RESULTS: After multiple regression analysis, repeated late decelerations on cardiotocography (OR: 2.4; 95% CI: 1.4-4.1) and prolonged second stage of labor (OR: 3.3; 95% CI: 1.3-8.3) were associated with AS5min < 7, as well as neonatal respiratory distress (OR: 3.0; 95% CI: 1.3-6.9), orotracheal intubation (OR: 2.5; 95% CI: 1.2-4.8), need for NICU (OR: 9.5; 95% CI: 6.7-16.8), and hypoxic-ischemic-encephalopathy (OR: 14.1; 95% CI: 3.6-54.7). No other antenatal factors were associated with AS5min < 7 (p > 0.05). CONCLUSION: Repeated late decelerations and prolonged second stage of labor in the low-risk population are predictors of AS5min < 7, a situation associated with increased risk of neonatal respiratory distress, need for mechanical ventilatory support and NICU, and hypoxic-ischemic-encephalopathy.


OBJETIVO: Avaliar a associação entre índice de Apgar menor que sete no 5º minuto, os fatores pré-natais e resultados pós-natais. MÉTODOS: Trata-se de estudo retrospectivo com 27.252 recém-nascidos em maternidade escola com população de baixo risco obstétrico, de janeiro de 2003 a dezembro de 2010. Prontuários de todos os casos com índice de Apgar < 7 no 5º minuto (n = 121; - 0,4%) e de 363 casos com Apgar > 7 no 5º minuto, escolhidos ao acaso, foram revisados. Os principais desfechos estudados foram: óbito neonatal, insuficiência respiratória neonatal, necessidade de intubação orotraqueal e de unidade terapia intensiva (UTI) neonatal e encefalopatia hipóxico-isquêmica. RESULTADOS: Após análise de regressão múltipla, desacelerações tardias (DIP II) (OR: 2,4; IC95%: 1,4-4,1) e período expulsivo prolongado (OR: 3,3; IC 95%: 1,3-8,3) se associaram com Apgar < 7 no 5º minuto; assim como com insuficiência respiratória ao nascimento (OR: 3,0; IC 95%: 1,3-6,9), intubação traqueal (OR: 2,5; IC 95%: 1,2-4,8), necessidade de UTI neonatal (OR: 9,5; IC 95%: 6,7-16,8) e encefalopatia hipóxico-isquêmica (OR: 14,1; IC 95%: 3,6-54,7). Nenhuma outra variável prénatal se associou com Apgar < 7 no 5º minuto (p < 0,05). CONCLUSÃO: DIP II e período expulsivo prolongado estão associados com Apgar < 7 no 5º minuto em população obstétrica de baixo risco; situação essa relacionada com maior risco de insuficiência respiratória no parto, necessidade de suporte ventilatório e encefalopatia hipóxico-isquêmica.


Subject(s)
Adolescent , Adult , Female , Humans , Infant, Newborn , Pregnancy , Young Adult , Apgar Score , Hypoxia-Ischemia, Brain/diagnosis , Respiratory Distress Syndrome, Newborn/diagnosis , Brazil/epidemiology , Cerebral Palsy/diagnosis , Cerebral Palsy/etiology , Hypoxia-Ischemia, Brain/etiology , Infant Mortality , Labor Stage, Second , Maternal Age , Retrospective Studies , Risk Assessment , Respiratory Distress Syndrome, Newborn/etiology , Term Birth/physiology
6.
Rev. med. (Säo Paulo) ; 88(1): 58-65, jan.-mar. 2009. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-525112

ABSTRACT

Objetivo: avaliar o potencial dos diferentes índices volumétricos de pulmões de fetos com hérnia diafragmática congênita isolada (HDC) medidos pela ultrassonografia tridimensional (US-3D) para predizer o resultado perinatal. Forma de estudo: Cinquenta e cinco fetos apresentando HDC foram avaliados pela US-3D entre janeiro de 2002 e maio de 2007. Os volumes pulmonares foram calculados pelo método rotacional na ultrassonografia tridimensional nos fetos com HDC (volumes observados) e comparados com aqueles descritos previamente em fetos normais (volumes esperados para determinada idade gestacional).


Objective: To evaluate the potencial of different lung mesurements using three-dimensional ultrasonography (3DUS) to predict perinatal outcome in cases of isolated congenital diaphragmatic hernia (CDH). Study design: Fifty-five fetuses presenting isolated CDH were prospectively evaluated by 3DUS between January 2002 and May 2007. Observed/expected total, contralateral and ipsilateral fetal lung volume ratios TFLV, CFLV and IFLV, respectively were calculated using the VOCAL™ technique and ultrasonographic fetal total lung volume to body weight ratio (US-FLW)...


Subject(s)
Humans , Female , Pregnancy , Prenatal Diagnosis , Fetus/ultrastructure , Hernia, Diaphragmatic/congenital , Imaging, Three-Dimensional , Lung Diseases/congenital , Lung/abnormalities , Ultrasonography, Prenatal
8.
Clinics ; 64(2): 91-96, 2009. ilus, tab
Article in English | LILACS | ID: lil-505369

ABSTRACT

OBJECTIVE: To report our initial institutional experience with fetoscopic laser photocoagulation of placental anastomoses in severe twin-twin transfusion syndrome using a 1.0 mm endoscope. METHODS: Between July 2006 and June 2008, 19 monochorionic diamniotic twin pregnancies complicated by severe TTTS (Quintero stages III and IV) underwent fetoscopic laser therapy. Perinatal data were prospectively collected and compared according to the Quintero stages. RESULTS: Nine patients were classified as stage III and ten as stage IV. The Mean gestational ages at diagnosis and procedure were 20 (range: 17-25) and 22.0 (range: 19.0-26.0) weeks, respectively, with no statistical difference between the two groups. Preterm premature rupture of the membranes occurred in two cases (10.5 percent), and spontaneous preterm delivery in eight (42.1 percent). Overall mean gestational age at delivery was 32.1 (range: 26.0-38.0) weeks. Prematurity was more severe in stage IV patients (p<0.01). Among all cases, the overall survival rate was 52.6 percent, and the percentages of pregnancies with survival of both babies and at least one twin were 26.3 percent and 78.9 percent, respectively. In the case of stage III patients, the overall survival rate was 61.1 percent. Of the stage III pregnancies, 33.3 percent resulted in both babies surviving, and 88.9 percent of these pregnancies resulted in at least one surviving twin. For stage IV, as the corresponding statistics were 45.0 percent, 20.0 percent and 70.0 percent respectively. CONCLUSIONS: Our initial institutional experience with 1.0 mm fetoscopic laser therapy for severe TTTS showed results similar to those reported in the literature for larger endoscopes.


Subject(s)
Female , Humans , Infant, Newborn , Male , Pregnancy , Fetofetal Transfusion/surgery , Fetoscopy/methods , Laser Therapy/methods , Light Coagulation/methods , Fetofetal Transfusion , Gestational Age , Pregnancy Outcome , Premature Birth , Prospective Studies , Severity of Illness Index , Survival Rate , Twins, Monozygotic
9.
São Paulo med. j ; 126(4): 239-241, July 2008. ilus, graf
Article in English | LILACS | ID: lil-494269

ABSTRACT

CONTEXT: Macrocystic adenomatoid malformation of the lung can cause severe mediastinal shift, hydrops and polyhydramnios, thereby increasing the risk of perinatal deaths. After 33 weeks of gestation, repeated puncturing of the cyst is recommended. We present a case in which a cyst-amniotic shunt was placed instead of performing this procedure. CASE REPORT: A cyst-amniotic shunt was placed at 33 weeks of gestation because of a large macrocystic adenomatoid malformation of the lung associated with severe mediastinal shift and polyhydramnios. Although it was confirmed that the catheter was in the correct place, the cyst increased in size again two weeks later, associated with repetition of polyhydramnios. It was postulated that the catheter was blocked, and we chose to place another catheter instead of performing repeated punctures. The cystic volume, polyhydramnios and mediastinal shift regressed progressively. At 38.5 weeks, a 3,310/g male infant was delivered without presenting any respiratory distress. The infant underwent thoracotomy on the 15th day of life. Thus, in the present study, we discuss the possibility of placing a cyst-amniotic shunt instead of performing repeated cystic punctures, even at a gestational age close to full term.


CONTEXTO: A malformação adenomatóide do pulmão tipo macrocística pode causar compressão mediastinal grave, hidropisia e polihidrâmnio aumentando a chance de óbito perinatal. Após a 33ª semana de gestação, recomenda-se realizar punções repetidas do cisto. Apresentamos um caso em que um dreno cístico-amniótico foi colocado e as punções foram evitadas. RELATO DE CASO: Um dreno cístico-amniótico foi colocado na 33ª semana de gestação devido a grande malfomação adenomatóide cística do pulmão associada a desvio de mediastino grave e polihidrâmnio. Apesar de o cateter ter sido identificado no local correto, o cisto voltou a crescer duas semanas após, repetindo o polihidrâmnio. Postulou-se que o cateter estava obstruído e optamos por colocar um novo cateter ao invés de realizar punções repetidas desse cisto. Foi observada regressão progressiva do volume do cisto, do polihidrâmnio e do desvio de mediastino. Na 38ª semana e meia, um menino de 3.310 g nasceu sem apresentar dificuldade respiratória, sendo submetido a toracotomia no 15º dia de vida. Portanto, no presente estudo, discute-se sobre a possibilidade de colocação do dreno cístico-amniótico no lugar de realizar punções repetidas do cisto mesmo em idades gestacionais próximas do termo.


Subject(s)
Adult , Female , Humans , Infant, Newborn , Male , Pregnancy , Catheters, Indwelling , Cystic Adenomatoid Malformation of Lung, Congenital/therapy , Fetal Diseases/therapy , Cystic Adenomatoid Malformation of Lung, Congenital/diagnosis , Fetal Diseases/diagnosis , Fetal Therapies/methods , Polyhydramnios , Pregnancy Outcome
11.
Femina ; 35(8): 507-512, ago. 2007. ilus
Article in Portuguese | LILACS | ID: lil-481963

ABSTRACT

Nesta revisão são apresentados os recentes métodos ultra-sonográficos aplicados na avaliação de estruturas torácicas fetais e suas anomalias. Serão revisados o volume pulmonar fetal por ultra-sonografia tridimensional (3D), a análise da parede torácica por imagem reconstruída em 3D e o modo imagem 3D para esqueleto, a avaliação dos vasos intratorácicos por ultrasonografia power Doppler 3D, a análise da anatomia cardíaca por imagem temporoespacial tridimensional em tempo real (4D) - STICtm, a identificação de estruturas intratorácicas normais e anormais por imagem de contraste de volume e a avaliação do coração e dos grandes vasos por modo de imagem invertido em 3D e 4D.


Subject(s)
Pregnancy , Respiratory System Abnormalities , Heart Defects, Congenital , Thoracic Diseases , Echocardiography, Four-Dimensional , Fetus/abnormalities , Imaging, Three-Dimensional/methods , Imaging, Three-Dimensional/trends , Lung Volume Measurements/methods , Ultrasonography, Prenatal
15.
Clinics ; 61(3): 197-202, June 2006. tab
Article in English | LILACS | ID: lil-430904

ABSTRACT

OBJETIVO: Avaliar os resultados neonatais dos casos de hérnia diafragmática congênita com diagnóstico pré-natal.PACIENTES E MÉTODOS: De janeiro de 1995 a dezembro de 2003 foram revisados os dados de 38 fetos com hérnia diafragmática diagnosticada durante o período pré-natal na Unidade de Medicina Fetal do Departamento de Obstetrícia e Ginecologia da Faculdade de Medicina da Universidade de São Paulo. Os dados pré-natais analisados foram: idade gestacional no diagnóstico, cariótipo fetal, lado da lesão, presença de malformação estrutural associada, herniação hepática e desvio garve de mediastino. Os dados perinatais foram avaliados consultando os prontuários médicos ou por contato telefônico. RESULTADOS: A idade gestacional média no diagnóstico foi de 29 semanas (16-37). Trinta (79%) casos apresentavam lesão à esquerda e 8 (21%) à direita. Malformações estruturais associadas foram observadas em 21 (55%) casos, dos quais 12 fetos apresentaram cariótipo normal, enquanto 9 exibiram anomalias cromossômicas. Hérnia diafragmática isolada foi identificada em 17 (457%) casos. A taxa de mortalidade geral foi de 92%. A taxa de óbito fetal, neomorto precoce, neomorto tardio e sobrevivente após 28 dias de vida foram respectivamente: (i) para o grupo com malformação estrutural associada e cariótipo normal, de 42%, 50%, 0% e 8%; (ii) para os casos com cromossomopatia, de 56%, 44%, 0% e 0%; (iii) para os casos com lesões isoladas de 0%, 76%, 12% e 12%. Na hérnia diafragmática congênita isolada, a mortalidade neonatal foi de 88%. CONCLUSÃO: Em nosso serviço, a mortalidade perinatal nos casos de hérnia diafragmática diagnosticada durante o pré-natal é muito alta. Óbitos neonatais precoces estão associados com presença de outros defeitos estruturais ou anomalias cromossômicas. Nos casos de HDC isolada, a mortalidade está relacionada à presença de fígado herniado, lado direito da lesão e desvio grave de mediastino.


Subject(s)
Female , Humans , Infant, Newborn , Pregnancy , Abnormalities, Multiple , Chromosome Aberrations , Hernia, Diaphragmatic , Ultrasonography, Prenatal , Brazil , Hernia, Diaphragmatic/congenital , Hernia, Diaphragmatic/mortality , Hernia, Diaphragmatic , Karyotyping , Pregnancy Outcome , Prognosis , Retrospective Studies
17.
Clinics ; 60(5): 407-414, Oct. 2005. tab, graf
Article in English | LILACS | ID: lil-414791

ABSTRACT

Esta revisão busca reúne estudos sobre a eficácia da aspirina em baixas doses na prevenção da pré-eclâmpsia em pacientes de alto e baixo risco. Identificamos estudos clínicos randomizados controlados usando baixas doses de aspirina para prevenir a pré-eclâmpsia, publicados no MEDLINE. Vinte e dois estudos preencheram nossos critérios de inclusão. Dividimos os estudos de acordo com a população estudada em dois grupos: estudos com mulheres de baixo risco para pré-eclâmpsia e estudos com pacientes de alto risco. A principal medida de efeito foi a incidência de pré-eclâmpsia em pacientes que usaram placebo ou aspirina, na qual os riscos relativos e os intervalos de confiança de 95% foram calculados para os grupos de pacientes de baixo e de alto risco para pré-eclâmpsia. Um total de 33.598 pacientes foram estudadas, dentre as quais cinco estudos com 16.700 pacientes de baixo risco e 17 estudos incluindo 16.898 pacientes de alto risco. As incidências de pré-eclâmpsia no geral, no grupo de baixo e no de alto risco foram de 6,40% (2.150/33.598), 3,75% (626/17.700), e 9,01% (1.524/16.898), respectivamente. Baixas doses de aspirina não tiveram efeito estatístico significante na redução da incidência de pré-eclâmpsia em pacientes de baixo risco (RR=0.95, 95%CI = 0.81-1.11), porém apresentaram pequenos benefícios em mulheres de alto risco (RR=0.87, 95%CI=0.79-0.96). Esta análise leva à conclusão de que baixas doses de aspirina têm pequeno efeito na redução da incidência da pré-eclâmpsia em pacientes com alto risco de desenvolver a doença.


Subject(s)
Humans , Female , Pregnancy , Aspirin/administration & dosage , Platelet Aggregation Inhibitors/administration & dosage , Pregnancy, High-Risk , Pre-Eclampsia/prevention & control , Drug Administration Schedule , Pre-Eclampsia/etiology , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors
18.
Rev. bras. ginecol. obstet ; 24(9): 601-608, out. 2002. tab
Article in Portuguese | LILACS | ID: lil-331578

ABSTRACT

Objetivo: avaliar o valor de parâmetros ultra-sonográficos para o diagnóstico da síndrome de Down fetal (T21), com a finalidade de permitir sua aplicação na prática clínica rotineira. Métodos: estudo do tipo coorte transversal prospectivo, utilizando múltiplos parâmetros ultra-sonográficos para predição da T21. Foram avaliados 1662 exames ultra-sonográficos no estudo de coorte e outros 289 exames como amostra diferencial para testar a curva de normalidade, de outubro de 1993 a novembro de 2000. A análise estatística se baseou no cálculo das variabilidades intra e interoperadores, na construção das curvas de normalidade dos parâmetros e provas de validação destas, nos cálculos de sensibilidade, especificidade, risco relativo, razão de probabilidade e dos valores preditivos pós-teste. Resultados: entre os 1662 casos do estudo, ocorreram 22 casos (1,32 por cento) de fetos com T21. As curvas de normalidades foram construídas para os parâmetros espessura nucal, relação fêmur/pé e comprimento dos ossos próprios do nariz, sendo que a pelve renal obedeceu a distribuição semiquantitativa e o nível de corte estabelecido foi de 4,0 mm. A partir do cálculo da razão de probabilidade e da incidência de T21 nas diversas idades maternas, construiu-se tabela para risco pós-teste dos parâmetros ultra-sonográficos estudados. Conclusões: foram estabelecidas as curvas de normalidade e os índices para cálculo de risco populacional da síndrome de Down fetal utilizando diferentes idades maternas e os fatores multiplicadores por nós propostos. Não foi possível estabelecer curva de normalidade para o parâmetro medida da pelve renal, pois seus resultados tiveram comportamento semiquantitativo, tendo sido, portanto, analisados por faixa de normalidade


Subject(s)
Humans , Female , Pregnancy , Adult , Down Syndrome , Ultrasonography, Prenatal
20.
Rev. bras. ginecol. obstet ; 23(9): 561-566, out. 2001. ilus, tab
Article in Portuguese | LILACS | ID: lil-299197

ABSTRACT

Objetivos: avaliar casos de fenda facial fetal quanto ao tipo de lesäo, associaçäo com outras malformaçöes e aneuploidias. Métodos: as fendas faciais foram estudadas quanto a idade materna e antecedentes, idade gestacional no diagnóstico, lado da lesäo, tipo de lesäo, presença de malformaçöes associadas e/ou aneuploidias, mortalidade e seguimento pós-natal. Resultados: em 40 fetos com fenda, a lesäo era labial pura em 18 casos (45 por cento), labiopalatina em 19 (47,5 por cento) e palatina em 3 (7,5 por cento). Em 10 casos a fenda era isolada (25 por cento), todas unilaterais. No grupo de malformaçöes associadas, a aneuploidia esteve presente em 10/30 (33,33 por ento). A lesäo labiopalatina predominou neste grupo (18/30 - 60 por cento), seguida por fenda bilateral (8/30 - 26,7 por cento) e mediana (10/30 - 33,3 por cento). Conclusöes: as fendas faciais constituíram excelente marcador para malformaçöes associadas e aneuploidias fetais. Casos de fendas faciais devem ser encaminhados para centros especializados para que se realizem adequados exames ultra-sonográfico e genético tecendo em seguida a conduta. O caráter isolado da fenda facial esteve associado a excelente prognóstico.


Subject(s)
Humans , Male , Female , Infant, Newborn , Adolescent , Adult , Cleft Lip , Cleft Palate , Prenatal Diagnosis , Fetus , Ultrasonography, Prenatal
SELECTION OF CITATIONS
SEARCH DETAIL